Hong-jin GUO, Jian-jun HAO, Ting WANG, Zhi-xin CHENG
College of Information and Electronical Engineering, Shandong University of Science and Technology, Qingdao 266510, China
Abstract—The principle for blood pressure measurement using pulse transit time is introduced in this paper. And the math model of synergetics theory is studied in detail .The synergetics theory is applied in the analysis of blood pressure measurement data. The simulation results show that the application of synergetics theory is helpful to judge the normal blood pressure, and the accuracy is up to 80%.
Keywords—pulse wave; synergetics theor; Blood pressure measurement
Manuscript Number: 1674-8042(2010)supp.-0155-05
dio: 10.3969/j.issn1674-8042.2010.supp..42
References
[1] Luo Xueju. The detection and treatment of hypertension People's Medical Publishing House, Beijing, 2004J. Clerk Maxwell, A Treatise on Electricity and Magnetism, 3rd ed., vol. 2. Oxford: Clarendon, 1892, pp.68–73.
[2] Shimada K, Kario K, Umeda Y. Early morning sure in blood pressure , Blood pressure monitoring, 2001, pp, 349-353.
[3] Pan Yishan, Jia Xiaobo, Cui Changkui, Xiao Xiaochun. “Analyses of Pulse Wave Propagation in Arteries”, Applied Mathematics and Mechanics, pp, 230-236, 2006.
[4] Zhu Wen, Ruan Xiao sheng, Liang Zhongqing. The relationship between pulse wave propagation speed and other factors in elastic pipe, J Zhejiang Med Univ, pp, 154-156, 1996, Aprial.
[5] L Dingli, Pan Yi, Chen Hang. “The establishment of a non-invasive continuous blood pressure measure system based on pulse transit time”, 2nd International Conference on Bioinformatics and Biomedical Engineering, iCBBE , pp, 1624-1627, 2008.
[6] Bramble JC, Hill AV. “The velocity of the pulse wave in man”, ProcR Soc Lond B Biol Sci, pp 298-306, 1992.Electronic Publication: Digital Object Identifiers (DOIs).
[7] R.A.Payne, C.N.Symeonides, D.J.Webb etal. “Pulse transit time measured from the ECG, an unreliable marker of beat-to-beat blood pressure”. J Appl Physiol pp, 136-141, 2006.
[8] King, D.Coghlan, etal. “Transcutaneous measurement of pulse wave velocity and mean blood pressure in man”, Blood flow measurement, London:sector, pp 40-43, 1972.
Blood flow measurement, London:sector, pp 40-43, 1972.
[9] Jung Soo Kim, Young Joon Chee, Ju Wan Park, Jin Wook Choi and Kwang Suk Park. “A new approach for non-invasive monitoring of blood pressure on a toliet seat”, Physiol, Meas, pp 230~211, 2006, March.
[9] Jung Soo Kim, Young Joon Chee, Ju Wan Park, Jin Wook Choi and Kwang Suk Park. “A new approach for non-invasive monitoring of blood pressure on a toliet seat”, Physiol, Meas, pp 230~211, 2006, March.
[10] LI Ding-li, CHEN Yu-quan, XING Lei, LI Yan, YAN Hong, CHEN Hang; YE Shu-ming. “A Non-invasive Continuous Blood Pressure Measurement System Based on Pulse Wave Velocity”, Space Medicine & Medical Engineering, pp, 417-419, 2008, May.
[11] Guo Yinjing. “ information fusion method and application in Human complex system”, Beijing, Beijing Institute of Technology, 2004.
[12] Dingguo Chen, Gao Jun, et al. “Blurred Image Restoration Based on Synergetic Patten Recognition”, In Image Matching and Analysis, Proceedings of SPIE, Vol 4552, pp 166-171, 2001.
[full text view]