此页面上的内容需要较新版本的 Adobe Flash Player。

获取 Adobe Flash Player

Application of RFID to Underground LNG Supply System


 

Sang-wook HAN,  Su-ri PARK,  Byung-jick KIM

 

(Dept. of Chemical Engineering, Soongsil University, Seoul 156-743, Korea)

 

Abstract—In order to reduce the gas accident due to third party digging, applicability of RFID to underground facility was investigated. Stable recognition depth of RFID tag were measured to be 60 , 50, 50, 25 cm in the medium of acrylic resin, soil, 5 cm-thick-concrete+soil, and water respectively. And 24 bit RFID metal tag can hold the LNG pipe data of construction date, material and thickness, burying depth, and ID No. Application of RFID to underground LNG supply system will not only reduce the gas accidents due to third party digging but also improve the maintenance efficiency.

 

Key words—RFID metal tag; recognition depth; LNG supply network; frequency analysis; third-party digging

 

Manuscript Number: 1674-8042(2011)supp1.-0060-05

 

doi: 10.3969/j.issn.1674-8042.2011.supp1.013

 

References

 

[1]Oh J S, Park J S, Kwon J R. Selecting the wireless communication methods for establishing ubiquitous city-gas facilities in Korea.
[2]Lee S K, Choi J W, Uhm J H, et al. New gas safety engineering. DongHwa Co., 2009: 18-28.
[3]Lee S K. Gas explosion prevention engineering. Ajin Co., 2009: 119-140, 210-212.
[4]Oh J S, Park J S, Kwon J R. Developing network infrastructure and smart service for safety management of city-gas facilities.
[5]Yun Y-G. Study on reform of the regulations concerning distance from the ground for the buried natural gas pipelines. 2008.
[6]Korea Gas Safety Corporation. http://www.kgs.or.kr.
[7]Korea Gas Corporation. http://www.kogas.or.kr.
[8]Jung S-K, Lee K-H, Kim H-S, et al. RFID frequency use plan researches. National IT Industry Promotion Agency.
[9]Kim D-S. RFID frequency utilization and standardization trends. National IT Industry Promotion Agency/[IITA], J. of Radio wave, 2004,Vol. 117.

 

 